Super Scientific Industries
Super Scientific Industries
Send Email
0804764498472% Response Rate
Search

Home » Our Products » Electrical Engineering Equipments


Electrical Engineering Equipments

Electrical Engineering Equipments are sought for all engineering related operations. They have wide range of applications and simplify the complexities to great extent. These equipment are offered at market leading rates.


This category included manufacturers, exporters, traders, distributors of Digital Testing Measuring Instruments e.g Oscilloscope, Oscillators, Function Generator, DC Regulated Power Supply, VTVM, LCR Meter, Digital Milli Ohm Meter, Digital pH/mV Meter, Digital Frequency Counter, DPM's for Volt, Amp. & Freq., H.V. Tester, Electronic Training Board, Components & Accessories for Electronic Lab, Calibrators Test & Measuring Instruments, LCR Meters, Voltage Breakdown Tester, Power Measurement Meter, Function Generators, DC Power Supplies, Communication Labs, Decade Boxes, Digital DC Watt Meters, Digital Transformer Ratio Meters, Digital Flow Meters, Digital AH Meters, Digital Ratemeter Totalisers, Digital Temperature Controllers, Digital Humidity Controller, Digital Lux Meter etc. 



Engineering College Lab Equipments

REQUEST CALLBACK

Engineering College Lab Equipments
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

leading manufacturer Engineering College Lab Instruments & Training Models, Engineering Equipments Manufacturers, Engineering Equipments Supplies, Engineering Equipments, Engineering Equipments India, Indian Engineering Equipments, Engineering Equipments Suppliers,Engineering Equipments, Engineering Training Models, Technical Teaching Equipment for Engineering, Engineering Educational Equipments, Air Conditioning Lab Equipments Supplies, Air Conditioning Lab Equipments India, Air Conditioning Lab Equipments, Air Conditioning Lab Equipments Supplier, Air Conditioning Lab Equipments Manufacturer, Indian Air Conditioning Lab Equipments, Engineering Instruments, Supplier, Engineering, College, Instruments
Send Bulk Enquiry

Electric Vehicle (Two Wheeler) study Trainer

REQUEST CALLBACK

Electric Vehicle (Two Wheeler) study Trainer
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 99,000 / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity01 Piece
Charging Time4-5 Hour
Battery Typelithium ion battery, MOSFET based Charger
Operating Voltage48V
BrandSSI

Set up designed to study the connection procedure and testing procedure of electric 2 wheeler set up using various components of electric vehicle like battery , BLDC Hub Motor , drive etc , Set up consists of
MotorMotor Type : BLDC Hub MotorRIM/HUB Size : 10InchVoltage : 36VMotor Power : 250W or 1000WMaximum speed : 35-40KMPHSensor : 3 Numbers of Hall sensorTire : Brand New
Send Bulk Enquiry

3 Phase AC Machine with Loading Arrangement

REQUEST CALLBACK

3 Phase AC Machine with Loading Arrangement
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

his is a 3-phase AC machine. This is mechanically coupled to a breakdrum to provide loading. The shaft of the machine is coupled a drum. In turn the drum is connected to mechanical weighing pan by means of a belt. Rotating the screws provided on either sides of the belt can adjust the belt tension. There by it is possible to load the shaft of the 3-phase motor with a defined tension. The difference in the scale reading, provides the tension, the shaft is subjected to. As a result of this the current in the windings are varied. By noting the readings of the associated meters and the difference in the weighing pan readings, the load characters of the motor can be evaluated.
Send Bulk Enquiry

Three Phase Induction Motor with Eddy Current Loading System

REQUEST CALLBACK

Three Phase Induction Motor with Eddy Current Loading System
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 1.59 Lakh / PieceGet Latest Price

Product Details:
No Of PhaseThree Phase
Power Rating3 phase 415 v ac 15 amp

Three Phase Induction Motor with Eddy Current Loading System
SUPER-BC401M

Description:

 

 

The prime mover becomes the Ac induction motor under test. The dynamometer works loaded by Eddy current dynamometer provided in the Dynamo with the help of an exciter unit. This Model is the Industrial/Educational model suitable for demonstrating to students the complete know of the Basics, Components, Mechanicals, Loading methods, Torque evaluation, Loading scheme, Students can make connections of their own with the help of the terminations provided for study of features viz Coupling the motor to be tested, Starting methods, Speed-Torque, Excitation control of Dynamometer, Torque measurement.

 

Experiments:            

                                                                                                                                                                                    

Ø  Load testing of AC Motor

Ø  Torque calculation at various rpm

Ø  Efficiency Analysis

Ø  To operate the column under total reflux condition and estimate the minimum number of theoretical plates required.

 

 Technical Specifications:

 

Motor 

5 HP AC induction motor, Three Phase 415Volt 50HZ, 1440 RPM

Star Delta Connection

Starter 

Star Delta Starter 5 HP

Loading arrangement 

Eddy Current dynamometer 5 HP air cooled with torque and speed measurement device

Volt Meter 

Digital Voltmeters Ac 500volt 2 nos

Ammeter 

Digital Ammeter 30amp 2 nos

Wattmeter 

Digital wattmeter 2500Watt

RPM 

Digital RPM meter for rpm measurement

Patch Cords

4mm (Heavy Duty) 1MeterLength

Short Circuit protection

MCB

Send Bulk Enquiry

DC Motor With Loading Arrangement

REQUEST CALLBACK

DC Motor With Loading Arrangement
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

This is a DC motor with the above specifications. The shaft of this motor is coupled mechanically to a break drum. A belt moving over this break drum provides necessary torque to the shaft of the motor, and in turn loads the shaft with a finite torque. Two calibrated spring balances are connected to either side of the belt, which is moving over the break drum. This is a method to load the shaft of the motor with a loading arrangement. By taking reading on these spring balance readings, the loading value may be calculated.
Send Bulk Enquiry

Slip Ring Induction Motor

REQUEST CALLBACK

Slip Ring Induction Motor
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Slip Ring Induction Motor

1. Outer yoke made up of High grade cast iron MS Frame

2. High grade silicon stamping Stator with hydraulically pressed

3. Suitable copper conductor of best quality used for winding for both Stator and Rotor4. Skewed Rotor construction with dynamically balance ensuring low noise

5. Larger size of bearings for longer life and trouble free operations

6. Vacuum pressure impregnation for stator & rotor ensuring high insulation strength

7. Rotor and brake drum Pulley are Dynamically Balanced8. Gun Metal Slip rings with good quality carbon brushes are used

9. All the terminals on terminals Box are properly engraved

10. Sturdy base frame with heavy duty bolt and also highly accurate dial type spring balance to give proper readings of the machines.  All Slip Ring Induction Motors Confirming to ISS

11. Ratings: For 3ph, 415Volts, 50Hz. 2H.P to 7.5HP

12. Starting Methods: Rotor Resistance Starter with no volt and over load protection.    

Send Bulk Enquiry

DC Shunt Generator No Load Tests On DC Shunt Generator

REQUEST CALLBACK

DC Shunt Generator No Load Tests On DC Shunt Generator
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Open Circuit Test


Objective: To obtain the magnetization characteristic and therefore determine the critical field resistance and critical speed of the given dc shunt generator.



Preview: The EMF induced in a DC machine is proportional to the flux per pole, the number of conductors and speed. This EMF depends on speed and flux. As the flux increases the EMF increases beyond a point the flux gets saturated. The BH curve of the core depicts the magnetization curve of the machine.

(A) Critical Speed of a DC Shunt Generator


Objective: To determine the critical speed of a dc shunt generator. With the fixed excitation and variable speed, as the speed reduces the OCC proportionally slides down so that the no load voltage reduces. At a particular speed, called the critical speed, the OCC is tangential to the Rf line and as a result the generator fails to excite.


Preview: With the fixed excitation and variable speed, as the speed reduces the OCC proportionally slides down so that the no load voltage reduces. At a particular speed, called the critical speed, the OCC is tangential to the Rf line and as a result the generator fails to excite.

 

Equipment Required: All the measuring instruments associated with each experiment are industrial grade. These instruments are housed in an elegant cabinet as a package. Range of instruments and accessories (standard format)


1. 2HP Shunt machines mechanically coupled both are identical 220V 2HP 1500rpm.
2. 3-4 point DC Starter for the above
3. Suitable Loading rheostat
4. Digital tachometer
5. Suitable Double tube rheostat
6. Suitable Single tube rheostat
7. Suitable Digital Voltmeter DC
8. Suitable Digital Voltmeter DC
9. Suitable Digital Ammeter DC
10. Rectifier Unit 0-240V DC @ 1.5KVA with power failure protection.

 

Send Bulk Enquiry

Load Test On A DC Shunt Generator

REQUEST CALLBACK

Load Test On A DC Shunt Generator
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Objective: To obtain external characteristics of a DC shunt generator

 

Preview:The self excited DC shunt Generator is coupled to a DC motor, which acts as prime mover. Two characteristics are more important. The internal or total characteristic that gives the relation between the emf actually induced in the armature and the armature current. This is of interest mainly to the designer. The external characteristics called performance characteristics (also voltage regulating curve) which give the relation between the terminal voltage and load current. This curve lies below the internal characteristics due to armature drop. This is important in judging the suitability of a generator for a particular purpose. These characteristics can be obtained by a load test with total field resistance remaining fixed as the speed is to be kept constant.

 

Equipment Required: All the measuring instruments associated with each experiment are industrial grade. These instruments are housed in an elegant cabinet as a package. Range of instruments and accessories (standard format)

 

  • 2HP Shunt machines mechanically coupled both are identical 220V 2HP 1500rpm.
  • 3-4 point DC Starter for the above
  • Suitable Loading rheostats
  • Digital tachometer
  • Suitable double tube rheostat
  • Suitable single tube rheostat
  • Suitable digital Voltmeters DC
  • Suitable DC source –Rectifier unit.
Send Bulk Enquiry

Single Phase Transformer

REQUEST CALLBACK

Single Phase Transformer
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Single phase double wound copper transformer having primary 230VAC and secondary 115V AC with a rated capacity of 1KVA. The primary and secondary terminals are brought out for conducting laboratory experiment with legend printed for convenience. This is assembled in a powder coated MS metal box.

 

Specifications:


  • Primary : 230 V AC
  • Secondary with tappings at 86.6% and at 50% of primary voltage.
  • Rated capacity: 1KVA
  • Terminations: Separate 4mm Banana terminals at input and outputs
  • Enclosure: Powder coated MS metal cabinet, with separate screw terminal for earth connection. 
Send Bulk Enquiry

Inductive Load

REQUEST CALLBACK

Inductive Load
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Voltage utilized in industry are of either resisitive, inductive or capacitive types these provide various types of power factor and the power system behaves accordingly. Resistive load banks are used to provide braking effect or for Heat dissipation.
These have canthel wires wounded on porcelain tubes through which electricity is passed & current flows, normally for Resistive loads the Power factor is unity. This Model is the Industrial/Educational model suitable for demonstrating to students the complete know of the Basics, Loading provided in steps, Study of Efficiency & Maintenance of these Loads packaged in small rating. Students can make connections of their own with the help of the terminations provided. 

Technical Specs :
- Power ratings available : 1KW / 2KW / 5 KW / 10KW
- Voltage Primary : 440V AC 3Phase/ 220V AC Single phase /220V DC
- Enclosed in cabinet with Steps provided for loading, meters provided for each phase & terminations brought out on Banana terminals
Send Bulk Enquiry

Squirrel Cage Induction Motor

REQUEST CALLBACK

Product Price :Get Latest Price

Squirrel Cage Induction Motor 


1. Outer yoke made up of High grade cast iron frame.

2. High grade silicon stamping Stator with hydraulically pressed.

3. Dynamically balance dies casted Rotor of High grade Aluminum used.

4. Larger size of bearings for longer life and trouble free operations.

5. Vacuum pressure impregnation for stator - ensuring high insulation strength.

6. All the terminals on terminals Box are properly engraved.

7. Brake drum pulley are Dynamically Balanced.

8. Sturdy base frame with heavy duty bolt with CP handle and also highly accurate dial type  spring balance to give proper readings of the machines.

9. Ratings: For 3ph, 415Volts, 50Hz.

 0.5H.P to 15HP.10.  Ratings: for 1ph 220V, 50Hz.                  

capacitor Start / Run Motor 0.5H.P to 2 HP.


Send Bulk Enquiry

 
X


Explore More Products

Contact via E-mail
Contact via SMS
Kush Pundir (Business Development Manager)
Super Scientific Industries
64 New Ajit Nagar , Tanghri Bandha , Near C Lal Hospital , Ambala Cantt, Sadar Bazar
Ambala - 133001, Haryana, India
Call Us: 
Call Response Rate: 72%
Share Us :



Home  |   Know Us   |  Our Products  |  Site Map  |   Contact Us

© Super Scientific Industries. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Super Scientific Industries