Electrical Engineering Equipments are sought for all engineering related operations. They have wide range of applications and simplify the complexities to great extent. These equipment are offered at market leading rates.
This category included manufacturers, exporters, traders, distributors of Digital Testing Measuring Instruments e.g Oscilloscope, Oscillators, Function Generator, DC Regulated Power Supply, VTVM, LCR Meter, Digital Milli Ohm Meter, Digital pH/mV Meter, Digital Frequency Counter, DPM's for Volt, Amp. & Freq., H.V. Tester, Electronic Training Board, Components & Accessories for Electronic Lab, Calibrators Test & Measuring Instruments, LCR Meters, Voltage Breakdown Tester, Power Measurement Meter, Function Generators, DC Power Supplies, Communication Labs, Decade Boxes, Digital DC Watt Meters, Digital Transformer Ratio Meters, Digital Flow Meters, Digital AH Meters, Digital Ratemeter Totalisers, Digital Temperature Controllers, Digital Humidity Controller, Digital Lux Meter etc.
Product Price :Get Latest Price
leading manufacturer Engineering College Lab Instruments & Training Models, Engineering Equipments Manufacturers, Engineering Equipments Supplies, Engineering Equipments, Engineering Equipments India, Indian Engineering Equipments, Engineering Equipments Suppliers,Engineering Equipments, Engineering Training Models, Technical Teaching Equipment for Engineering, Engineering Educational Equipments, Air Conditioning Lab Equipments Supplies, Air Conditioning Lab Equipments India, Air Conditioning Lab Equipments, Air Conditioning Lab Equipments Supplier, Air Conditioning Lab Equipments Manufacturer, Indian Air Conditioning Lab Equipments, Engineering Instruments, Supplier, Engineering, College, InstrumentsApprox. Rs 99,000 / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 01 Piece |
Battery Type | lithium ion battery, MOSFET based Charger |
Charging Time | 4-5 Hour |
Operating Voltage | 48V |
Brand | SSI |
Product Price :Get Latest Price
his is a 3-phase AC machine. This is mechanically coupled to a breakdrum to provide loading. The shaft of the machine is coupled a drum. In turn the drum is connected to mechanical weighing pan by means of a belt. Rotating the screws provided on either sides of the belt can adjust the belt tension. There by it is possible to load the shaft of the 3-phase motor with a defined tension. The difference in the scale reading, provides the tension, the shaft is subjected to. As a result of this the current in the windings are varied. By noting the readings of the associated meters and the difference in the weighing pan readings, the load characters of the motor can be evaluated.Approx. Rs 1.59 Lakh / PieceGet Latest Price
Product Details:No Of Phase | Three Phase |
Power Rating | 3 phase 415 v ac 15 amp |
Description:
The prime mover becomes the Ac induction motor under test. The dynamometer works loaded by Eddy current dynamometer provided in the Dynamo with the help of an exciter unit. This Model is the Industrial/Educational model suitable for demonstrating to students the complete know of the Basics, Components, Mechanicals, Loading methods, Torque evaluation, Loading scheme, Students can make connections of their own with the help of the terminations provided for study of features viz Coupling the motor to be tested, Starting methods, Speed-Torque, Excitation control of Dynamometer, Torque measurement.
Experiments:
Ø Load testing of AC Motor
Ø Torque calculation at various rpm
Ø Efficiency Analysis
Ø To operate the column under total reflux condition and estimate the minimum number of theoretical plates required.
Technical Specifications:
Motor | 5 HP AC induction motor, Three Phase 415Volt 50HZ, 1440 RPM Star Delta Connection |
Starter | Star Delta Starter 5 HP |
Loading arrangement | Eddy Current dynamometer 5 HP air cooled with torque and speed measurement device |
Volt Meter | Digital Voltmeters Ac 500volt 2 nos |
Ammeter | Digital Ammeter 30amp 2 nos |
Wattmeter | Digital wattmeter 2500Watt |
RPM | Digital RPM meter for rpm measurement |
Patch Cords | 4mm (Heavy Duty) 1MeterLength |
Short Circuit protection | MCB |
Product Price :Get Latest Price
This is a DC motor with the above specifications. The shaft of this motor is coupled mechanically to a break drum. A belt moving over this break drum provides necessary torque to the shaft of the motor, and in turn loads the shaft with a finite torque. Two calibrated spring balances are connected to either side of the belt, which is moving over the break drum. This is a method to load the shaft of the motor with a loading arrangement. By taking reading on these spring balance readings, the loading value may be calculated.Product Price :Get Latest Price
Objective: To obtain external characteristics of a DC shunt generator
Preview:The self excited DC shunt Generator is coupled to a DC motor, which acts as prime mover. Two characteristics are more important. The internal or total characteristic that gives the relation between the emf actually induced in the armature and the armature current. This is of interest mainly to the designer. The external characteristics called performance characteristics (also voltage regulating curve) which give the relation between the terminal voltage and load current. This curve lies below the internal characteristics due to armature drop. This is important in judging the suitability of a generator for a particular purpose. These characteristics can be obtained by a load test with total field resistance remaining fixed as the speed is to be kept constant.
Equipment Required: All the measuring instruments associated with each experiment are industrial grade. These instruments are housed in an elegant cabinet as a package. Range of instruments and accessories (standard format)
Product Price :Get Latest Price
Single phase double wound copper transformer having primary 230VAC and secondary 115V AC with a rated capacity of 1KVA. The primary and secondary terminals are brought out for conducting laboratory experiment with legend printed for convenience. This is assembled in a powder coated MS metal box.
Specifications:
Product Price :Get Latest Price
Slip Ring Induction Motor
1. Outer yoke made up of High grade cast iron MS Frame
2. High grade silicon stamping Stator with hydraulically pressed
3. Suitable copper conductor of best quality used for winding for both Stator and Rotor4. Skewed Rotor construction with dynamically balance ensuring low noise
5. Larger size of bearings for longer life and trouble free operations
6. Vacuum pressure impregnation for stator & rotor ensuring high insulation strength
7. Rotor and brake drum Pulley are Dynamically Balanced8. Gun Metal Slip rings with good quality carbon brushes are used
9. All the terminals on terminals Box are properly engraved
10. Sturdy base frame with heavy duty bolt and also highly accurate dial type spring balance to give proper readings of the machines. All Slip Ring Induction Motors Confirming to ISS
11. Ratings: For 3ph, 415Volts, 50Hz. 2H.P to 7.5HP
12. Starting Methods: Rotor Resistance Starter with no volt and over load protection.
Product Price :Get Latest Price
Open Circuit Test
Objective: To obtain the magnetization characteristic and therefore determine the critical field resistance and critical speed of the given dc shunt generator.
Preview: The EMF induced in a DC machine is proportional to the flux per pole, the number of conductors and speed. This EMF depends on speed and flux. As the flux increases the EMF increases beyond a point the flux gets saturated. The BH curve of the core depicts the magnetization curve of the machine.
(A) Critical Speed of a DC Shunt Generator
Objective: To determine the critical speed of a dc shunt generator. With the fixed excitation and variable speed, as the speed reduces the OCC proportionally slides down so that the no load voltage reduces. At a particular speed, called the critical speed, the OCC is tangential to the Rf line and as a result the generator fails to excite.
Preview: With the fixed excitation and variable speed, as the speed reduces the OCC proportionally slides down so that the no load voltage reduces. At a particular speed, called the critical speed, the OCC is tangential to the Rf line and as a result the generator fails to excite.
Equipment Required: All the measuring instruments associated with each experiment are industrial grade. These instruments are housed in an elegant cabinet as a package. Range of instruments and accessories (standard format)
1. 2HP Shunt machines mechanically coupled both are identical 220V 2HP 1500rpm.
2. 3-4 point DC Starter for the above
3. Suitable Loading rheostat
4. Digital tachometer
5. Suitable Double tube rheostat
6. Suitable Single tube rheostat
7. Suitable Digital Voltmeter DC
8. Suitable Digital Voltmeter DC
9. Suitable Digital Ammeter DC
10. Rectifier Unit 0-240V DC @ 1.5KVA with power failure protection.
Product Price :Get Latest Price
Voltage utilized in industry are of either resisitive, inductive or capacitive types these provide various types of power factor and the power system behaves accordingly. Resistive load banks are used to provide braking effect or for Heat dissipation.Squirrel Cage Induction Motor
1. Outer yoke made up of High grade cast iron frame.
2. High grade silicon stamping Stator with hydraulically pressed.
3. Dynamically balance dies casted Rotor of High grade Aluminum used.
4. Larger size of bearings for longer life and trouble free operations.
5. Vacuum pressure impregnation for stator - ensuring high insulation strength.
6. All the terminals on terminals Box are properly engraved.
7. Brake drum pulley are Dynamically Balanced.
8. Sturdy base frame with heavy duty bolt with CP handle and also highly accurate dial type spring balance to give proper readings of the machines.
9. Ratings: For 3ph, 415Volts, 50Hz.
0.5H.P to 15HP.10. Ratings: for 1ph 220V, 50Hz.
capacitor Start / Run Motor 0.5H.P to 2 HP.
Explore More Products
© Super Scientific Industries. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited