Product Price :Get Latest Price
Digital Automtic Polarimeter |
• Measurement Scales: ... Angle of Rotation, International Sugar Scale (without temperature compensation) ... International Sugar Scale (with Automatic Temperature Compensation) |
• Measurement Range: ... Angle of Rotation -89.99 to +89.99° ... International Sugar Scale -130.00 to +130.00°Z |
• Measurement Accuracy: ... Angle of Rotation : 0.01° ... International Sugar Scale ±0.03°Z |
• Password Accessability |
• Has feature to perform three sample averaging |
Product Price :Get Latest Price
Semi-automatic Polarimeter are suitable for measuring the proportion, purity, concentration and content of rotatory organic material.
Applications :
Agricultural Industry: For analyzing the element of agricultural antibiotic, microbial pesticide and the starch content of farm produce. Pharmaceutical Industry: For analyzing antibiotics, vitamins, glucose. Food Industry: For determining the productive process of sugars, soy sauce or other food additives as well as examining their finished products. Determining the sugar content in food. Petroleum Industry: For measuring mineral oil and monitoring petroleum fermentation technology.
Cosmetics: For measuring essential oils. Hygiene Industry: Clinical analysis of diabetes.
Specification :
Measuring Range : |
-180° ~ +180° |
Approx. Rs 1.20 Lakh / PieceGet Latest Price
Used in medical, pharmaceutical and chemical research laboratories. Consist of a imported half shade nicol polariser, analyser, 100mm. Diameter circular scale divided in degrees 0-360 Deg. x 1 Deg. And a sugar scale divided –30 Deg. To + 130 Deg. X 1 Deg. ISS, a divided micrometer drum is given to read 0.05 Deg. (3 minutes) and 0.1 Deg. ISS, the scale is properly illuminated for taking readings, the body is very sturdy and separate sodium lamp is stand is provided. Complete with polarimeter tube, bubble traps at the center, 200mm. Sodium lamp with stand and transformer
Research Polarimeter (400 mm) SSI , Tube Length 400 MM
Additional Information:
Product Price :Get Latest Price
POLARIMETER- Manual Type Code No.: SS--535 |
Measuring Range: -180° ~+180° Scale Interval: 1° Vernier Scale Interval: 0.05° Magnification factor of the magnifying glass: 4 times Light Source: Sodium lamp Optical Wavelength: 589.44mm Tube Length: 100mm, 200mm Balance Time: 5 minutes Power: 220V/50HZ, 110V/60Hz Dimensions: 500mm X 135mm X 330mm Weight: 5kg |
Product Price :Get Latest Price
For accurate measurement of index of refraction of transparent liquids, solids and solutions.For use in Sugar, Ghee and Oil Mills Pharmaceuticals and Chemical Laboratories, JAM Factories and Distillaries etc. Measuring range 1.3000 to 1.7000. Measurement of Sugar 0% to 95% Complete |
Designed for the Accurate & quick Examination of the Refractive Indices & Mean Dispersion of Liquids. Solids & Oil. |
ND Range : N.D. 1.3000 to N.D. 1. 7000 in steps of 0.001 Accuracy : 0.0002 Sugar Percentage : 0 to 95% in steps of 1 Division Accuracy : ± 0.5% Temperature : 0 – 50º C |
Approx. Rs 60,000 / UnitGet Latest Price
Automatic tissue processor is designed to provide a solution to the rapid processing of tissue in histology labs. Atmp17 removes all the water from a tissue sample and replaces it with paraffin wax with optimum speed to curtail damage to the tissue caused by dehydration and shrinkage.
Technical aspect:
Otissue processor consists of a highly accurate microprocessor based control. O provision for automatic adjustable delay start. 12 stage timing sequence programmed for duration ranging fro1 min to 9 hrs, 59 min, in steps of 1 min. o precise and accurate pid controller with pt100 temperature sensor. O the microprocessor based pid controller maintains temperature between 50°c to 65 °c. O the main unit proceeds to next stage from 9th onward only after the set temperature is attained, o safety systems functioning at 10th, 11th and 12th stages. If the wax is melted, the tissue processor automatically proceeds from stage 9 to 10 and so on o if the wax is not melted the tissue processor indicates “wax not melted / temperature insufficient”. Pecial feature: oempower to do most potentially hazardous procedures on just a click. Otissues are processed simultaneously with one program. Osystem is prudent and well guarded. Odesign is stout and proposes unswerving performance on smallest space. Oastonishing price versus performance ratio.
Additional Information:
Product Price :Get Latest Price
The Laboratory Refractometer DR 194(A) is designed for the measurement of refractive index, average dispersion of liquids, solids and for determination of percentage sugar sugar content in aques solutions. In view of high accuracy achieved with the use of even a few drops of liquid or substance under test the refractometric measurement present a convenient andeconomical method of testing. They find their applications wherever the components of mixture show various indexes of refraction. The refractometric measurements are applied to research and control works in chemical and food industry. TECHNICAL SPECIFICATIONSProduct Price :Get Latest Price
|
Product Price :Get Latest Price
The spectrometer consists of a graduated circle, generally fixed in a horizontal position, to which is attached a collimator and a telescope. The collimator consists of a tube containing an achromatic lens at one end and a vertical slit at the principal focus of the lens. The movable arm carries an astronomical telescope which is always directed towards the centre of the graduated circle. The position of the telescope with reference to the fixed circle may be read by means of a Vernier. Above the centre of the graduated circle is a horizontal table, called the table of the spectrometer, which is capable of rotation about the vertical axis of the circle. The position of the circle table can be determined by means of the Vernier.
6"circle read by two opposite venires to one minute of an arc Complete in wooden box
7"circle read by two opposite verniersto 1 min. of an arc.Completein wooden box.
Approx. Rs 36,000 / PieceGet Latest Price
Technical Specification
Model | SSI-2002 |
Optical System | Double Beam, Grating 1200 lines/mm |
Wavelength Range | 190 nm-1100nm |
Spectral Bandwidth | 1 nm |
Wavelength Accuracy | ± 0.1nm@656.1nm, ±0.3nm@all |
Wavelength Repeatability | ≤0.1nm |
Photometric Accuracy | 0.2%T(0~100%T),±0.002A(0-0.5A),±0.004A(0.5-1A) |
Photometric Repeatability | ≤0.15%T(0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A) |
Photometric Range | 0-200%T, 0.3~3A, 0-9999C (0-9999F) |
Stray Light | ≤0.03%T@220nm, 360 nm |
Stability | ±0.0003A/h@500nm |
Baseline Flatness | ±0.001A |
Noise | 0.0005A@500nm |
Work Mode | T%, Abs, Conc, E, |
Scanning Speed | Hi, Med, Low (Max. 3000nm/min) |
Wavelength Setting | Auto |
Display | 10.1” TFT Colored Capacitive Touch Screen |
Light Source | Imported Xenon Lamp |
Detector | Imported Silicon Photodiode |
Cuvette Holder | 10mm single hole cell holder |
Output | USB drive, USB host, RS232 |
Power | AC 220V/50Hz or AC 110V/60Hz |
Shipping Size | 810*660*390mm |
|
Approx. Rs 14,500 / PieceGet Latest Price
Specifications
Model | SSI-2003 |
1) Wavelength Range: | 325 -1000nm |
2) Light Source Lamp: | Tungsten Halogen Lamp 20W/12V |
3) Wavelength Accuracy: | ±2 nm |
4) Wavelength Reproducibility: | 1 nm |
5) Band width: | 2 nm |
6) Photometric Accuracy: | ±0.5%(T) |
7) Photometric Reproducibility: | 0.2%(T) |
8) Stray Light: | ±0.2%(T) |
9) Noise: | ±0.2%(T) |
10) Size | (L*W*H) Main Unit : 370*320*190mm Carton : 450*420*280mm |
11) Weight | N.W -7 KG G.W - 9.5 KG |
12) Power Requirement: | 220V/110V±10% 50/60 Hz |
13) Interface: | RS232 serial & parallel interface |
Standard Configuration
* Main Instrument | : 1 Unit |
* Operational Manual | : 1 No. |
* Power cable | : 1 No. |
* Glass Cell 10mm | : 4 No. |
* Software CD | : 1 No. |
* RS 232 Cable | : 1 No. |
* Dust Cover | : 1 No. |
Approx. Rs 31,000 / PieceGet Latest Price
Super AUTOCOLLIMATOR is a sensitive, extremely accurate optical instrument which is precisely used in optical workshops, inspection departments and quality control labs.
Application:-It is basically a comparator where we compare optical element like slabs and prisms for flatness. It is used for very small angle measurements of the order of minutes.
Specification:-Objective focal length | 220mm |
Clear aperture | 40mm |
Magnification | 11x |
Measuring range axis | 60-0-60 min. in X-Y |
Least Deviation on reticle | 1 minute of arc |
Least Division on micrometer drum | 2" of arc |
Additional Information:
Used in medical, pharmaceutical and chemical research laboratories. Consist of a imported half shade nicol polariser, analyser, 100mm. Diameter circular scale divided in degrees 0-360 Deg. x 1 Deg. And a sugar scale divided –30 Deg. To + 130 Deg. X 1 Deg. ISS, a divided micrometer drum is given to read 0.05 Deg. (3 minutes) and 0.1 Deg. ISS, the scale is properly illuminated for taking readings, the body is very sturdy and separate sodium lamp is stand is provided. Complete with polarimeter tube, bubble traps at the center, 200mm. Sodium lamp with stand and transformer.Tube Length 400 MM
Explore More Products
© Super Scientific Industries. All Rights Reserved (Terms of Use)